Pulse Vacuum Sterilizer

Labtro Pulse Vacuum Sterilizers ensure effective sterilization of heat-sensitive materials. They feature compact designs with chamber sizes ranging from 25 to 100 Liters. These sterilizers operate at a maximum temperature of 134°C for efficient sterilization. Their advanced pulse vacuum technology allows for thorough air removal and steam penetration. Our Pulse Vacuum Sterilizer are essential for sterilization in laboratories and medical facilities.

Volume

Chamber Measurement

External Measurement

Sterilization Temperature Range

  • Pulse Vacuum Sterilizer LT-VS401

    • Volume: 0.25m3
    • Chamber Measurement: 800×600×600
    • External Measurement: 1100×1320×1700
    • Steam: 0.4 to 0.8Mpa
    • Water: 0.15 to 0.3Mpa
  • Pulse Vacuum Sterilizer LT-VS402

    • Volume: 0.36m3
    • Chamber Measurement: 1000×600×600
    • External Measurement: 1300×1320×1700
    • Steam: 0.4 to 0.8Mpa
    • Water: 0.15 to 0.3Mpa
  • Pulse Vacuum Sterilizer LT-VS403

    • Volume: 0.6m3
    • Chamber Measurement: 1200×610×910
    • External Measurement: 1500×1320×1950
    • Steam: 0.4 to 0.8Mpa
    • Water: 0.15 to 0.3Mpa
  • Pulse Vacuum Sterilizer LT-VS404
    • Volume: 0.8m3
    • Chamber Measurement: 1450×610×910
    • External Measurement: 1750×1320×1950
    • Steam: 0.4 to 0.8Mpa
    • Water: 0.15 to 0.3Mpa
  • Pulse Vacuum Sterilizer LT-VS405
    • Volume: 0.36 m³
    • Design Temperature: 144°C
    • Sterilization Temperature Range: 105°C to 139°C
    • Inner Cavity Design Pressure: -0.1 to 0.3 MPa
    • Inner Cavity Working Pressure: -0.1 / 0.25 MPa
  • Pulse Vacuum Sterilizer LT-VS406

    • Volume: 0.36 m³
    • Design Temperature: 144°C
    • Sterilization Temperature Range: 105°C to 139°C
    • Inner Cavity Design Pressure: -0.1 to 0.3 MPa
    • Inner Cavity Working Pressure: -0.1 / 0.25 MPa
  • Pulse Vacuum Sterilizer LT-VS407

    • Volume: 0.36 m³
    • Design Temperature: 144°C
    • Sterilization Temperature Range: 105°C to 139°C
    • Inner Cavity Design Pressure: -0.1 to 0.3 MPa
    • Inner Cavity Working Pressure: -0.1 / 0.25 MPa
  • Pulse Vacuum Sterilizer LT-VS408

    • Volume: 0.36 m³
    • Design Temperature: 144°C
    • Sterilization Temperature Range: 105°C to 139°C
    • Inner Cavity Design Pressure: -0.1 to 0.3 MPa
    • Inner Cavity Working Pressure: -0.1 / 0.25 MPa
  • Pulse Vacuum Sterilizer LT-VS409
    • Volume: 0.6 m³
    • Design Temperature: 144°C
    • Sterilization Temperature Range: 105°C to 139°C
    • Inner Cavity Design Pressure: -0.1 to 0.3 MPa
    • Inner Cavity Working Pressure: -0.1 / 0.25 MPa