Biochemistry Analyzer LT-BA501

Biochemistry Analyzer LT-BA501 performs up to 120 tests/hr with sample volumes ranging from 2 to 30 µl. It operates efficiently within an optimal temperature range to ensure consistent and accurate performance. Equipped with automatic washing and disposable cuvette options, this analyzer enhances testing flexibility. Our Biochemistry Analyzer features a probe with anti-collision protection and liquid-level detection for precise sample handling.

Qty:

$ 3806

Specifications

Sample Volume 2 to 30 µL
Test Speed 120 tests/hour
Test Mode Kinetic, Endpoint, Fixed time, Turbidimetry, Absorbance
Reagent Volume 20 to 350 µL
Working Temperature 10°C to 30°C
Humidity ≤ 85%
Wavelength 8 Wavelengths: 340, 405, 450, 510, 546, 578, 630, 700 nm
Absorbance Range 0 to 4.000 Abs
Absorbance Precision ≤ 0.00001 Abs
Repeatability CV Less than 1%
Carry-Over Less than 0.1%
Sample Positions 24 + 5 (using original tube)
Calibration Position 1
QC Position 1
ST Position 1
Reagent Positions 54 (27 for 6mL; 27 for 24mL)
Cuvettes Position 81 (can be reusable)
Water Consumption 5L/H for Automatic washing mode, 2.5L/H for Disposable cuvette mode
Quality Control Curve x̅, SD, CV%, L-J quality control curve for every test item
LED Lamp Lifespan ≥ 10,000 hours
Printer Internal thermal sensitive printer
Interface RS-232
Power Supply 100 to 240VAC, 50/60Hz, 100VA
Dimension 350 × 605 × 330 mm
Packaging Dimension 390 × 680 × 400 mm
Net Weight 22 Kg
Gross Weight 27 Kg

Features

  • High-resolution Color LCD touchscreen
  • Long-lasting & energy-efficient LED lamp
  • Real-time curve display
  • Efficient data management
  • High-pressure probe flush for optimal cleanliness

Application

Biochemistry Analyzer LT-BA501 is essential in clinical laboratories, research facilities, and diagnostic centres for efficient and precise biochemical testing across various applications, including enzyme assays, protein analysis, and metabolic studies.

Expert Help Desk

Automatic Chemistry Analyzer

Labtro Automatic Chemistry Analyzer are designed to perform wide range of chemical analysis on biological samples. They utilize halogen lamp as light source which facilitates photometric measurement systems. Their automation enhances efficiency, accuracy, and speed of laboratory testing processes. They are integrated with automatic malfunction alarms, collision sensor, and liquid-level sensor. Our Automatic Chemistry Analyzer can handle multiple samples at same time.

Automatic Chemistry Analyzer LT-CA701

  • Throughput : 300 Tests/hour
  • Analytical System : Random Access
  • Method : Endpoint, Rate, Fixed Time, Immunoturbidimetric, 1-2 reagent/serum blank

Automatic Chemistry Analyzer LT-CA702

  • Throughput : 400 Tests/Hour
  • Analytical System : Random Access with Direct Reading System
  • Method : Endpoint, Kinetic, Fixed Time, Immunoturbidimetric, 1-2 Reagent/Serum Blank, Multistandard

Hematology Analyzer

Labtro Hematology Analyzer measures complete blood count and aids in diagnosing infections, inflammation, and blood cancers. They are fully computerized, allowing for rapid and accurate processing of multiple specimens. These analyzers maintain sample integrity through automatic washing. They utilize recyclable and eco-friendly reagents, reducing waste. Our Hematology Analyzer measures blood components, including red, white blood cells and platelets, to diagnose blood-related health issues.

Hematology Analyzer LT-HA601
  • Throughput : 60 tests/hour
  • Sample volume : 13 μl (whole blood), 20 μl (prediluted blood)
  • Assay Items : 22 Parameters, including 3-part differential of WBC
Hematology Analyzer LT-HA602
  • Throughput : 60 samples/hr
  • Sample Volume : ≤20 µl
  • Parameters : WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDWP-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#

Hematology Analyzer LT-HA603

  • Throughput : 60 tests/hour
  • Sample Volume : ≤10 µl
  • Parameters : WBC, Lym#, Mid#, Gran#, Lym%,

Gas Analyzer

Labtro Gas Analyzer measures concentration of various gases in mixture. They feature self-detection function with audio-visual alarm and infrared sensor. They are highly sensitive, accurate, precise, and provide real-time monitoring. They are integrated with computer for detailed analysis, reporting, and storing data. Our Gas Analyzer are suitable for petroleum and chemical industries, metallurgical processes, medical and healthcare departments.

Gas Analyzer LT-GA301

  • Gas Detected : CO₂, CO, CH₄, SO₂, NOx
  • Detection Principle : Electrochemistry (SO₂, NOx); Infrared ray (CO₂, CO, CH₄)
  • Measure Range : CO₂: 0–100% VOL, CO: 0–100% VOL, CH₄: 0–100% VOL, NOx: 0–5000 ppm, SO₂: 0–5000 ppm

Hemoglobin Analyzer

Labtro Hemoglobin Analyzer integrates advanced microfluidics technology for precise monitoring of blood disorders. It provides accurate hemoglobin measurements with a minimal blood sample and accommodates various sample types, making it versatile for multiple laboratory applications. Offering rapid testing, it delivers quick results and is equipped with comprehensive data management features for efficient storage and analysis of hemoglobin test data.

Hemoglobin Analyzer LT-AHA301
  • Blood Sample Volume : 10 μL
  • Blood Sample Material : Capillary /venous whole blood
  • Parameters : Hemoglobin (Hb), Hematocrit (HCT)

Nitrite Nitrogen Analyzer

Advanced Industrial Online Nitrite Nitrogen Analyzers provide precise, real-time monitoring of water quality with intelligent microprocessor control and UV nitrite nitrogen sensors. Ideal for environmental protection, wastewater treatment, and industrial sewage applications, these analyzers deliver accurate measurements across a wide ppm or mg/L range. Reliable, automated, and easy to integrate, they ensure consistent nitrite nitrogen detection, helping facilities optimize operations and maintain compliance.

Nitrite Nitrogen Analyzer LT-NNA801
  • Measurement Range : 0 to 999.00 mg/L
  • Resolution : 0.01 mg/L, 0.01 ppm
  • Measurement Accuracy : ±3% F.S.

Nitrite Nitrogen Analyzer LT-NNA802

  • Measuring Range : Concentration: 0.4–100 mg/L (depending on electrode range, pH 2.5–11) Temperature: 0–50 °C
  • Resolution : Concentration: 0.01 / 0.1 / 1 mg/L Temperature: 0.1 °C
  • Accuracy / Basic Error : Concentration: ±5% Temperature: ±0.3 °C