Overview
Labtro Analytical HPLC System LT-AHS103 operates with 70 MPa maximum pressure keeps sample analysis moving from injection through compound separation and detector response in one continuous process. Organized solvent delivery maintains a steady analytical sequence while generated chromatograms support result verification and record keeping. Continuous sample processing improves laboratory throughput with clear, repeatable analytical data for routine testing.
Technical Specifications
| Pump Type | Binary high-pressure constant flow pump | Pump Flow Range | 0.001 to 10.000 mL/min |
|---|---|---|---|
| Pump Flow Accuracy | ≤ ±0.2% | Pump Flow Stability | RSD ≤ 0.06% |
| Pump Maximum Pressure | 70 MPa | Pump Pressure Display Error | ±0.3 MPa |
| Pump Pressure Pulsation | ≤ 0.1 MPa | Pump Gradient Mixing Accuracy | ≤ ±0.5% |
| Pump Gradient Composition Accuracy | ≤ 0.1% RSD | Pump Gradient Composition Range | 0 to 100% |
| Pump Communication | UDP | Pump Power Consumption | 300 W |
| Pump Power Supply | AC 110–220 V, 50–60 Hz | Pump Dimension | 450 × 350 × 180 mm |
| Pump Weight | 18 kg | Autosampler Type | Automatic liquid sampler |
| Autosampler Injection Range | 0–100 μL (Standard), 1–2000 μL (Optional) | Autosampler Injection Speed | ≤10 s |
| Autosampler Sample Residue | <0.002% | Autosampler Injection Repeatability | RSD <0.2% |
| Autosampler Capacity | 120 × 2 mL or 210 × 1 mL vials | Autosampler Maximum Pressure | 45 MPa |
| Autosampler Power Consumption | 30 W | Autosampler Power Supply | AC 110–220 V, 50–60 Hz |
| Autosampler Dimension | 440 × 378 × 180 mm | Autosampler Weight | 13 kg |
| UV Detector Type | UV-Visible detector | Detector Wavelength Range | 190 to 800 nm |
| Detector Wavelength Accuracy | ±1.0 nm | Detector Wavelength Repeatability | ≤ ±0.1 nm |
| Detector Spectral Bandwidth | 8 nm | Detector Noise | ≤ ±0.25 × 10⁻⁵ AU |
| Drift | ≤0.5 × 10⁻⁴ AU/h | Detector Linearity | ≥2.5 AU |
| Minimum Detectable Concentration | 1 × 10⁻⁹ g/mL | Light Source | Deuterium and Tungsten lamps |
| Detector Maximum Pressure | 1500 psi | Detector Sampling Frequency | 5–80 Hz |
| Detector Time Constant | 0.1–5.0 s | Detector Power Consumption | 100 W |
| Detector Power Supply | AC 110–220 V, 50–60 Hz | Detector Dimension | 440 × 378 × 160 mm |
| Weight | 10 kg | Diode Array Detector Type | Diode Array Detector (DAD) |
| Array Elements | 512 | Wavelength Range | 190 to 800 nm |
| Spectral Resolution | 2.4 nm | Array Resolution | 1.2 nm |
| Wavelength Accuracy | ±1.0 nm | Dynamic Noise | ≤ ±1.0 × 10⁻⁵ AU |
| Baseline Drift | 1.0 × 10⁻⁴ AU/h | Linearity | ≥2.0 AU |
| Lamp | Deuterium lamp | Detection Pool | 10 mm, 11 μL |
| Maximum Pressure | 1000 psi | Power Supply | AC 110–220 V, 50–60 Hz |
| Column Oven Type | Column oven | Temperature Range | Ambient +5°C to 99°C |
| Temperature Accuracy | ±0.1°C | Temperature Precision | ≤0.1°C |
| Communication | RS485 / UDP | Power Consumption | 110 W |
| Oven Power Supply | AC 220 V ±10%, 50 Hz | Dimension | 120 × 65 × 570 mm |
| Oven Weight | 4.2 kg |
Features & Applications
Key Features
Binary high-pressure solvent delivery
Stable gradient flow control
Precise flow regulation
Continuous laboratory operation
Integrated chromatography communication
Modular HPLC configuration
Applications
Product Details