Overview
Bilirubinometer LT-BM101 measures total bilirubin by analyzing the optical properties of a small blood sample. The collected blood is placed in a disposable 75 mm capillary tube and prepared for measurement. The analyzer directs light through the plasma using its bi-chromatic optical system. Measurements are taken at 450 nm and 578 nm to evaluate bilirubin-related color intensity. The reference wavelength helps compensate for background interference in the sample. The detected light signals are converted into an electrical measurement by the photometric system. The analyzer compares the measured optical response with the stored calibration reference. It then calculates the total bilirubin concentration from the difference between the two wavelength readings. The final result is shown clearly on the backlit LCD. A built-in thermal printer can immediately print the measured result for documentation. RS232 connectivity allows the result data to be transferred to an external system when required.
Technical Specifications
| Measurement Principle | Direct photometry | Measurement Range | 0 to 30 mg/dL |
|---|---|---|---|
| Intended Use | Quantitative determination of total bilirubin in blood | Photometer | Bi-chromatic |
| Measurement Wavelength | 450 nm and 578 nm | Light Source | Long-life white LED |
| Capillary Type | Disposable capillary | Capillary Size | 75 mm |
| Capillary Capacity | 60 µL | Capillary Diameter | 1.3 to 1.4 mm |
| Sample Volume | 40 to 45 µL | Display | 16 × 2 backlit LCD |
| Printer | Built-in 58 mm thermal printer | Interface | Standard RS232 |
| Power Supply | AC 100 to 240 V, 50/60 Hz; DC 12 V, 3 A | Operating Temperature | 10 to 30°C |
| Relative Humidity | ≤95% | Atmospheric Pressure | 860 to 1060 hPa |
| Optional Centrifuge Speed | 0 to 12,000 rpm | Maximum RCF | 15,300 × g |
| Optional Centrifuge Capacity | 24 × Φ1.5 × 75 mm capillaries | Net Weight | 2 kg |
| Dimension | 160mm*240mm*70mm | Packaging Dimension | 250(L)*190(W)*85(H)mm |
| Gross Weight | 5 kg |
Features & Applications
Key Features
Direct photometric measurement
↳ Determines total bilirubin concentration by analyzing plasma color against a calibrator
Bi-chromatic optical system
↳ Uses 450 nm and 578 nm wavelengths for bilirubin measurement
Low sample requirement
↳ Requires only 40 to 45 µL of blood sample for analysis
Disposable capillary measurement
↳ Supports 75 mm, 60 µL capillary tubes for convenient sample handling
Long-life white LED source
↳ Provides stable illumination for photometric measurement
Built-in thermal printer
↳ Provides immediate printed test results
RS232 interface
↳ Enables connection with compatible external systems
Applications
Neonatal Departments → Support laboratory bilirubin assessment in newborn-care workflows
Pediatric Laboratories → Assist bilirubin testing for pediatric patients
Clinical Chemistry Laboratories → Perform quantitative total bilirubin determination
Diagnostic Laboratories → Support routine blood bilirubin analysis
Healthcare Centers → Provide bilirubin measurement where small-volume blood samples are preferred