Air Sampler
Air Sampler
Autoclave
Autoclave
Balance
Balance
Microscope
Microscope
Centrifuge
Centrifuge
Bath
Bath
Photometer
Photometer
View All Categories
Search suggestions will appear here.
Get Quote 0
Menu
Get Quote
PRODUCT CATALOG
Biological Safety Cabinet Class II A2 LT-BSC207
BIOLOGICAL SAFETY CABINET CLASS II A2

Biological Safety Cabinet Class II A2 LT-BSC207

Labtro Biological Safety Cabinet Class II A2 LT-BSC207 draws room air inward through the front opening to create an air barrier that helps protect the operator from aerosols and contaminants generated inside the work zone. The incoming air mixes with internally recirculated air and is passed through the U15 ULPA downflow filter, which supplies clean vertical laminar airflow over the work surface to protect the samples. Approximately 70% of the filtered air is recirculated back through the cabinet, while the remaining 30% is discharged through a separate ULPA exhaust filter to protect the surrounding environment. An EC brushless motor with closed-loop airflow control continuously adjusts fan output to compensate for increasing filter resistance and maintain the specified inflow and downflow velocities. Integrated sensors monitor airflow, filter pressure, sash position, and fan performance, while the touchscreen displays operating conditions and activates audible and visual alarms if parameters move outside safe limits. After operation, the programmable 254 nm UV lamp can be used for work-zone decontamination when the cabinet is not in active use.

Class II Type A2 protection system
↳ Provides simultaneous personnel, product, and environmental protection

70% recirculation and 30% exhaust
↳ Maintains controlled containment while conserving conditioned laboratory air

Dual U15 ULPA filtration
↳ Independent downflow and exhaust filters provide >99.999% efficiency at 0.1 to 0.3 µm

Closed-loop airflow regulation
↳ EC brushless motor automatically compensates for filter loading to maintain stable airflow

Continuous airflow monitoring
↳ Tracks inflow and downflow velocities with integrated sensors

7-inch color touchscreen
↳ Displays airflow velocity, filter differential pressure, filter life, fan status, sash condition, timers, and alarms

Comprehensive alarm system
↳ Provides audible and visual warnings for airflow deviation, fan failure, sash position, filter blockage, and maintenance requirements

Removable SUS304 worktop
↳ Enables thorough cleaning and decontamination of the work surface and lower plenum

One-piece stainless-steel work chamber
↳ Large-radius corners minimize difficult-to-clean joints and support routine decontamination

10° ergonomic safety-glass sash
↳ Provides comfortable access and clear visibility during operation

Tempered-glass side panels
↳ Improve lateral visibility of the work zone

Programmable 254 nm UV sterilization
↳ Supports work-zone decontamination with sash and fan safety interlocks

Dual waterproof electrical outlets
↳ Allow operation of compatible small laboratory equipment inside the workspace

Height-adjustable support stand
↳ Provides stable and ergonomic cabinet positioning
02
PRODUCT INFORMATION

Overview

Labtro Biological Safety Cabinet Class II A2 LT-BSC207 draws room air inward through the front opening to create an air barrier that helps protect the operator from aerosols and contaminants generated inside the work zone. The incoming air mixes with internally recirculated air and is passed through the U15 ULPA downflow filter, which supplies clean vertical laminar airflow over the work surface to protect the samples. Approximately 70% of the filtered air is recirculated back through the cabinet, while the remaining 30% is discharged through a separate ULPA exhaust filter to protect the surrounding environment. An EC brushless motor with closed-loop airflow control continuously adjusts fan output to compensate for increasing filter resistance and maintain the specified inflow and downflow velocities. Integrated sensors monitor airflow, filter pressure, sash position, and fan performance, while the touchscreen displays operating conditions and activates audible and visual alarms if parameters move outside safe limits. After operation, the programmable 254 nm UV lamp can be used for work-zone decontamination when the cabinet is not in active use.

Biological Safety Cabinet Class II A2 LT-BSC207

Technical Specifications

Classification Class II Type A2 Protection Type Personnel, Product, and Environmental Protection
Airflow Pattern 70% Recirculation / 30% Exhaust Airflow Direction Vertical Laminar Downflow
Exhaust Direction Top Exhaust Average Inflow Velocity 0.50 m/s
Average Downflow Velocity 0.33 m/s Airflow Distribution Full-area homogeneous vertical downflow
Airflow Regulation Closed-loop Constant-Air-Volume Regulation Airflow Compensation Automatic compensation for filter loading
Airflow Monitoring Continuous inflow and downflow velocity monitoring Velocity Sensors Integrated
Velocity Meter Accuracy 0.001 m/s Blower / Motor EC Brushless DC Motor
Downflow Filter Independent ULPA Filter Exhaust Filter Independent ULPA Filter
Filtration Configuration Dual ULPA Filtration – Downflow and Exhaust ULPA Classification U15
Filtration Efficiency >99.999% at 0.1 to 0.3 µm Controller Microprocessor Control System
Display 7-inch Color Capacitive Touchscreen Displayed Airflow Parameters Inflow Velocity and Downflow Velocity
Filter Monitoring Filter Differential Pressure and Filter-Life Monitoring Fan Monitoring Fan Operating Status
Sash Monitoring Front Sash Position / Status Running-Time Display Supported
UV Timer Display Supported System Information Display Supported
Alarm Type Audible and Visual Inflow Alarm Inflow Velocity Outside Preset Limit
Downflow Alarm Downflow Velocity Outside Preset Limit Fan Alarm Fan / Blower Failure
Sash Alarm Sash Position Outside Safe Operating Range Filter Alarm Filter Blockage / High Resistance
Filter-Life Alarm Filter Lifetime / Maintenance Reminder Work Chamber Material 1.5 mm SUS304 / AISI 304 Stainless Steel
Work Chamber Design One-piece formed construction with large-radius coved corners Worktop Material SUS304 Stainless Steel
Worktop Type Removable without tools Worktop Cleaning Access Allows access to work surface and lower plenum for cleaning/decontamination
Side Panels Tempered Safety Glass Front Sash Material Laminated Shatterproof Safety Glass
Front Sash Design 10° Backward-Slanted Ergonomic Sash Working Sash Opening 180 mm
Maximum Sash Opening 530 mm Armrest Integrated Ergonomic Armrest
Main Body Material 1.2 mm Electro-Galvanized Steel Surface Treatment White Oven-Baked Electrostatic Powder-Coated Finish
Chemical Resistance Resistant to Standard Laboratory Disinfectants Illumination Type LED
Standard Illumination ≥700 lux Enhanced Illumination ≥900 lux configuration available
Lighting Design Low-heat, shadow-minimized illumination UV Lamp 254 nm Germicidal UV
UV Lamp Power 30 W UV Timer Programmable
UV Safety Interlock Interlocked with Front Sash and Fan Internal Electrical Sockets 2 Waterproof / Drip-Proof Sockets
Vibration Level ≤3 µm RMS Base Stand Height-Adjustable Support Frame
Power Supply AC 220 V ±10%, 50/60 Hz Electrical Requirement Dedicated Grounded Supply
Maximum Electrical Load 1500 VA Internal Work Area Dimensions 1300 × 672 × 630 mm
External Dimensions with Base Stand 1480 × 790 × 2080 mm Net Weight 270 kg
Packing Dimensions 1600 × 1020 × 1740 mm Gross Weight 302 kg
PRODUCT DETAILS

Features & Applications

PRODUCT BENEFITS

Key Features

Class II Type A2 protection system
↳ Provides simultaneous personnel, product, and environmental protection

70% recirculation and 30% exhaust
↳ Maintains controlled containment while conserving conditioned laboratory air

Dual U15 ULPA filtration
↳ Independent downflow and exhaust filters provide >99.999% efficiency at 0.1 to 0.3 µm

Closed-loop airflow regulation
↳ EC brushless motor automatically compensates for filter loading to maintain stable airflow

Continuous airflow monitoring
↳ Tracks inflow and downflow velocities with integrated sensors

7-inch color touchscreen
↳ Displays airflow velocity, filter differential pressure, filter life, fan status, sash condition, timers, and alarms

Comprehensive alarm system
↳ Provides audible and visual warnings for airflow deviation, fan failure, sash position, filter blockage, and maintenance requirements

Removable SUS304 worktop
↳ Enables thorough cleaning and decontamination of the work surface and lower plenum

One-piece stainless-steel work chamber
↳ Large-radius corners minimize difficult-to-clean joints and support routine decontamination

10° ergonomic safety-glass sash
↳ Provides comfortable access and clear visibility during operation

Tempered-glass side panels
↳ Improve lateral visibility of the work zone

Programmable 254 nm UV sterilization
↳ Supports work-zone decontamination with sash and fan safety interlocks

Dual waterproof electrical outlets
↳ Allow operation of compatible small laboratory equipment inside the workspace

Height-adjustable support stand
↳ Provides stable and ergonomic cabinet positioning

WHERE IT IS USED

Applications

Microbiology Laboratories → Handling microorganisms, cultures, media, and microbiological specimens

Clinical Laboratories → Processing potentially infectious diagnostic and patient samples

Cell Culture Laboratories → Aseptic handling of cells, tissue cultures, and related biological materials

Biotechnology Laboratories → DNA/RNA procedures, hybridization, media preparation, and biological research workflows

Pharmaceutical Laboratories → Microbiological quality control, sterile preparation, and biological sample handling

Hospital Laboratories → Controlled preparation and manipulation of clinical biological specimens

Biomedical Research Laboratories → Procedures requiring personnel, sample, and environmental containment

Quality Control Laboratories → Controlled microbiological testing and aseptic sample processing
PRODUCT INFORMATION

Product Details

Biological Safety Cabinet Class II A2 LT-BSC207
BIOLOGICAL SAFETY CABINET CLASS II A2

Biological Safety Cabinet Class II A2 LT-BSC207

Standard Accessories:

  • Height-Adjustable Base Stand
  • Downflow U15 ULPA Filter
  • Exhaust U15 ULPA Filter
  • 254 nm UV Germicidal Lamp
  • LED Illumination Lamp
  • 2 Waterproof Internal Electrical Sockets
  • 7-inch Touchscreen Controller
  • Airflow Velocity Sensors
  • Filter Differential-Pressure Monitoring System
  • Integrated Armrest
  • Power Cord / Electrical Connection

Optional Accessories:

Complete ULPA Filter Set
Spare UV Lamp
Spare LED Lamp

Request Product Information