Ductless Fume Hood LT-DLFH101
DUCTLESS FUME HOOD

Ductless Fume Hood LT-DLFH101

Labtro Ductless Fume Hood LT-DLFH101 provides filtered containment for laboratory procedures that generate chemical vapors, gases, and airborne contaminants. The system draws contaminated air from the work chamber through pre-filters and activated carbon filters, while the closed-loop airflow controller maintains an air velocity of 0.4 to 0.6 m/s. Its 7-inch LCD touchscreen displays operating parameters, while VOC, filter saturation, and fan failure alarms help monitor safe operation. Dual PSC blowers support controlled airflow, and the corrosion-resistant epoxy work surface provides a durable area for chemical handling. Optional organic, acidic, alkaline, chlorine-gas, and H14 HEPA filters allow the filtration system to be configured according to different laboratory applications.

Automatic closed-loop airflow control
↳ Maintains airflow velocity at 0.4 to 0.6 m/s
7-inch LCD touch screen
↳ Provides convenient monitoring and control of operating parameters
Dual VOC monitoring system
↳ Monitors laboratory air quality and filter saturation status
02
PRODUCT INFORMATION

Overview

<span style="background-color:rgb(252,252,252);color:rgb(13,13,13);">Labtro Ductless Fume Hood LT-DLFH101 provides filtered containment for laboratory procedures that generate chemical vapors, gases, and airborne contaminants. The system draws contaminated air from the work chamber through pre-filters and activated carbon filters, while the closed-loop airflow controller maintains an air velocity of 0.4 to 0.6 m/s. Its 7-inch LCD touchscreen displays operating parameters, while VOC, filter saturation, and fan failure alarms help monitor safe operation. Dual PSC blowers support controlled airflow, and the corrosion-resistant epoxy work surface provides a durable area for chemical handling. Optional organic, acidic, alkaline, chlorine-gas, and H14 HEPA filters allow the filtration system to be configured according to different laboratory applications.</span>

Ductless Fume Hood LT-DLFH101

Technical Specifications

Function Exhaust, Air Velocity Control Control System Automatic Closed-Loop Airflow Velocity Control
Display 7-inch LCD Touch Screen Airflow Velocity 0.4 to 0.6 m/s
Airflow Volume 260 m³/h Pre-Filter 2 pcs
Activated Carbon Filter 1 group, 2 pcs Maximum Filter Capacity 2 groups, 4 pcs
Alarm System Filter Saturation Alarm, VOC Alarm, Fan System Failure Alarm Environmental Monitoring Real-time Temperature and Humidity Monitoring
VOC Monitoring Dual VOC Probes Air Velocity Sensor Provided
Blower 2 × PSC Blowers Main Body Material Galvanized Steel Sheet, ≥1.5 mm
Surface Treatment Epoxy Resin Electrostatic Spraying Work Surface Epoxy Resin, Corrosion and High-temperature Resistant
Front and Side Window ≥8.0 mm Acrylic Board LED Lamp 16 W × 2
Maximum Consumption 120 W Power Supply AC 220 V ±10%, 50/60 Hz; AC 110 V ±10%, 60 Hz
Sound Emission ≤52 dB(A) External Size – Main Unit 1000 × 620 × 1100 mm
External Size – Base Cabinet 1000 × 600 × 690 mm Internal Size 980 × 570 × 775 mm
Optional Organic Gas Filter For CH₂O, H₂S, R-SH, CH₃CHO, SO₂, NOx, O₃ and VOCs Optional Acidic Gas Filter For H₂S, SO₂, NOx, HCl and HBr
Optional Alkaline Gas Filter For NH₃, CH₃NH₂ and (CH₃)₃N Optional Chlorine Gas Filter For Cl₂
Optional HEPA Filter H14 HEPA Filter Net Weight – Main Unit 114 kg
Gross Weight – Main Unit 144 kg Net Weight – Base Cabinet 62 kg
Gross Weight – Base Cabinet 82 kg Packaging Size – Main Unit 1060 × 680 × 1450 mm
Packaging Size – Base Cabinet 1060 × 620 × 900 mm
PRODUCT DETAILS

Features & Applications

PRODUCT BENEFITS

Key Features

Automatic closed-loop airflow control
↳ Maintains airflow velocity at 0.4 to 0.6 m/s

7-inch LCD touch screen
↳ Provides convenient monitoring and control of operating parameters

Dual VOC monitoring system
↳ Monitors laboratory air quality and filter saturation status

Filter saturation alarm
↳ Indicates when filter replacement may be required

Fan failure alarm
↳ Alerts users to abnormal blower operation

Multi-stage filtration system
↳ Uses pre-filters and activated carbon filters to capture contaminants and chemical vapors

Corrosion-resistant construction
↳ Epoxy-coated galvanized steel and epoxy work surface support chemical handling

Low-noise airflow system
↳ Operates at a sound level of ≤52 dB(A)

Optional specialized filtration
↳ Supports organic, acidic, alkaline, chlorine-gas, and H14 HEPA filters

WHERE IT IS USED

Applications

Chemical Laboratories → Handling procedures that generate chemical vapors and fumes
Pharmaceutical Laboratories → Containment during preparation and testing of chemical substances
Research Laboratories → Controlled handling of volatile and potentially hazardous compounds
Educational Laboratories → Safer performance of routine chemical experiments and demonstrations
Quality Control Laboratories → Sample preparation and reagent handling under filtered airflow
Industrial Laboratories → Handling acids, alkalis, VOCs, and other gaseous contaminants with suitable filtration
PRODUCT INFORMATION

Product Details

Ductless Fume Hood LT-DLFH101
DUCTLESS FUME HOOD

Ductless Fume Hood LT-DLFH101

Standard Accessories:

Base Cabinet; Activated Carbon Filter; Pre-Filter; LED Lamps; 7-inch LCD Touch Screen; PSC Blowers; Real-time Environmental Monitoring System; Air Velocity Sensor

Optional Accessories:

Organic Gas Filter
Acidic Gas Filter
Alkaline Gas Filter
Chlorine Gas Filter
HEPA Filter