Nucleic Acid Analyzer LT-NAA101
NUCLEIC ACID ANALYZER

Nucleic Acid Analyzer LT-NAA101

Labtro Nucleic Acid Analyzer LT-NAA101 is a fully automated molecular diagnostic system designed for nucleic acid extraction, PCR amplification, hybridization, detection, and result analysis. It combines PCR with reverse dot blot hybridization to identify target genetic sequences using microfluidic chip technology. The analyzer incorporates six detection modules and accommodates up to 24 samples per run. Automated reagent handling minimizes manual intervention and eliminates the need for precise pipetting during operation. Integrated temperature control provides heating and cooling rates of at least 1.5°C/s for efficient amplification. The system requires approximately 5 minutes of hands-on preparation, with a total turnaround time of about 3.5 hours. It supports HPV genotyping and detection of Mycobacterium tuberculosis and associated resistance genes. An integrated image detection system evaluates hybridization signals for qualitative interpretation. 

Six independent detection modulesProcesses up to 24 samples per runFully automated sample-to-result workflowIntegrated DNA extraction and PCR amplificationReverse dot blot hybridization detectionMicrofluidic chip-based processingOnly about 5 minutes of hands-on preparationApproximately 3.5-hour total turnaroundAutomatic reagent dispensingNo precise manual pipetting required during automated processingIntegrated positive and negative pressure controlRapid heating and cooling at ≥1.5°C/sIntegrated image detection and analysisAutomated 3D movement platformSupports multiplex genotype detectionHPV 24-type genotypingHPV 28-type genotypingMycobacterium tuberculosis detectionAssociated resistance-gene detectionImage display systemAutomated reagent systemPneumatic gas-path systemTemperature-control systemImage-detection system3D movable platformPCR amplification moduleMicrofluidic chip processing system
02
PRODUCT INFORMATION

Overview

Labtro Nucleic Acid Analyzer LT-NAA101 is a fully automated molecular diagnostic system designed for nucleic acid extraction, PCR amplification, hybridization, detection, and result analysis. It combines PCR with reverse dot blot hybridization to identify target genetic sequences using microfluidic chip technology. The analyzer incorporates six detection modules and accommodates up to 24 samples per run. Automated reagent handling minimizes manual intervention and eliminates the need for precise pipetting during operation. Integrated temperature control provides heating and cooling rates of at least 1.5°C/s for efficient amplification. The system requires approximately 5 minutes of hands-on preparation, with a total turnaround time of about 3.5 hours. It supports HPV genotyping and detection of Mycobacterium tuberculosis and associated resistance genes. An integrated image detection system evaluates hybridization signals for qualitative interpretation. 

Nucleic Acid Analyzer LT-NAA101

Technical Specifications

Detection Principle PCR and Reverse Dot Blot Hybridization Detection Modules 6 Modules
Sample Capacity Up to 24 Samples Workflow Sample-to-Answer Automated Genotyping
Sample Preparation Automated Nucleic Acid Extraction Automated DNA Extraction
PCR Amplification Automated Hybridization Automated Reverse Hybridization
Detection Method Microfluidic Chip-Based Detection Result Analysis Automatic Software Analysis
Result Reporting Automatic, Easy-to-Read Report Hands-On Time Approximately 5 min
Total Turnaround Time Approximately 3.5 hrs Heating Rate ≥1.5°C/s, from 50°C to 90°C
Cooling Rate ≥1.5°C/s, from 90°C to 50°C Reagent Handling Automated Reagent Processing
Fluid Handling Microfluidic Chip with Integrated Micro-Pumps Pneumatic Control Positive and Negative Pressure Control
Temperature Control Integrated Temperature Control System Image Detection Integrated Image Detection System
Movement System 3D Movable Platform Sample Loading Direct loading into designated sample position
Test Initiation Load sample and press start Sample Type Exfoliated Cervical Epithelial Cells
HPV Detection 24 / 28 Genotype Panels Additional Detection Mycobacterium tuberculosis and resistance genes
Electrical Requirement 230 V, 50 Hz Rated Power 600 VA
Maximum Operating Altitude ≤2300 m Dimensions 1000 × 610 × 690 ±10 mm
Weight 80 kg
PRODUCT DETAILS

Features & Applications

PRODUCT BENEFITS

Key Features

Six independent detection modulesProcesses up to 24 samples per runFully automated sample-to-result workflowIntegrated DNA extraction and PCR amplificationReverse dot blot hybridization detectionMicrofluidic chip-based processingOnly about 5 minutes of hands-on preparationApproximately 3.5-hour total turnaroundAutomatic reagent dispensingNo precise manual pipetting required during automated processingIntegrated positive and negative pressure controlRapid heating and cooling at ≥1.5°C/sIntegrated image detection and analysisAutomated 3D movement platformSupports multiplex genotype detectionHPV 24-type genotypingHPV 28-type genotypingMycobacterium tuberculosis detectionAssociated resistance-gene detectionImage display systemAutomated reagent systemPneumatic gas-path systemTemperature-control systemImage-detection system3D movable platformPCR amplification moduleMicrofluidic chip processing system

WHERE IT IS USED

Applications

HPV genotype screening
Molecular diagnostic laboratories
Cervical screening programs
Infectious disease testing
Mycobacterium tuberculosis detection
Drug-resistance gene detection
Clinical nucleic acid analysis
Molecular biology laboratories
PRODUCT INFORMATION

Product Details

Nucleic Acid Analyzer LT-NAA101
NUCLEIC ACID ANALYZER

Nucleic Acid Analyzer LT-NAA101

Optional Accessories:

  • External Printer 
  • HPV 24-Genotyping Microfluidic Chip Kit
  • HPV 28-Genotyping Microfluidic Chip Kit

Request Product Information